| SPECIFICATIONS: MCT 101-T TRANSMITTER |
|
|
|
| Measurement Range: |
|
0-60% |
|
DIMENSIONS: MCT 101-T Transmitter

SIDE VIEW

TOP VIEW

FRONT VIEW

REAR VIEW
Remote Display Unit
| Display: |
Numeric LCD |
| Pushbutton: |
Grab Sample Average |
| Enclosure: |
Cast Aluminium |
 |
| Measurement Accuracy: |
|
+/- 0.1% to 0.5% depending on tobacco type |
|
| Repeatability: |
|
+/- 0.2% |
|
| Sensor/Product distance: |
|
6-16 inches (150-400mm) |
|
| Calibration Codes: |
|
10 standard, up to 50 on request |
|
| Response Time: |
|
1-999 seconds. Three modes available Damping, Integration and Gated. |
|
| Power: |
|
90-260VAC 50/60 Hz, 40 watts 24VDC optional |
|
| Outputs: |
|
4-20 mA, 0-10 V, RS232 & RS485 |
|
| Weight: |
|
20 lbs. (9 Kg) |
|
|
|
|
|
| Operator Interfaces: Wall or Post Mounting |
|
| |
|
|
|
| Display: |
|
Alphanumeric Vacuum Fluorescent, readout in % moisture and temperature |
|
| Languages: |
|
English, plus one local, user selectable (Spanish, French, Portuguese, Italian, Polish, Russian, Chinese, etc.) |
|
| Power: |
|
From MCT 101-T Transmitter |
|
| Cable: |
|
10-ft (3 meters) standard, maximum 100 ft (30 meters) |
|
| Keypad: |
|
Keypad for user access to MCT 101-T settings, including calibrations, product codes and diagnostics. |
|
| Enclosure: |
|
Cast Aluminum |
|
| |
|
|
| Environmental: |
|
Ambient Temperature: |
|
0-50˚C (32˚-120˚F, to 80˚C (160˚F) with water or air cooling panel. |
|
| Enclosure: |
|
Cast Aluminum, IP-65 NEMA 4 |
|
| Window Purge: |
|
Airpurge Diffuser requires 5 psi and 2 l/m |
|
| |
|
|
|
| Maintenance: |
|
Warranty: |
|
24 months for all parts and labor. |
|
| Routine: |
|
None required. |
|
| Calibration: |
|
Pre-calibrated, no recalibration needed. |
|
| Calibration Verification: |
|
Calibration Check Standards |
|
| |
|
|
|
| CE Compliance: |
|
EMC directives EN50081-1 & EN50082-2, EN61010-1 Low Voltage directive. |
|
| |
|
|
|
| Data Bus & Software Interfaces: |
|
Optional Plug-In Interfaces: |
|
Ethernet TCP/IP, DeviceNet, Profibus, Modbus. |
|
| Software: |
|
Windows-based stand-alone program or OPC-DDE Server |
|